Contact:
|
|
|
|
Tel: +86-10-87709858
|
|
Fax: +86-10-87709228 |
|
E-mail:
info@farAsia.com.cn |
|
|
|
Add:
|
|
1401, No. 12 Bldg,
|
|
Panjiayuan Nanli,
|
|
Chaoyang, Beijing,
100021, China
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
TYPE S & TYOW SS
|
Type S
Part No. |
Type SS
Part No. |
Nominal Size
(inch) |
I.D
(mm) |
O.D
(mm) |
Bend Radius
(mm) |
Reeled Lengths (m) |
|
S00970140 |
SS00970140 |
1/4 ? |
9.7-10.2 |
13.5-14.0 |
25 |
50 |
|
S01230158 |
SS01230158 |
3/8? |
12.3-12.8 |
15.3-15.8 |
35 |
50 |
|
S01580193 |
SS01580193 |
1/2? |
15.8-16.3 |
18.7-19.3 |
40 |
50 |
|
S02080242 |
SS02080242 |
3/4? |
20.8-21.3 |
23.7-24.4 |
45 |
50 |
|
S02640298 |
SS02640298 |
1? |
26.4-27.1 |
29.2-29.8 |
55 |
50 |
|
S03500383 |
SS03500383 |
1-1/4? |
35.0-35.8 |
37.7-38.3 |
60 |
30 |
|
S04010440 |
SS04010440 |
1-1/2? |
40.1-40.6 |
43.4-44.0 |
90 |
30 |
|
S05130554 |
SS05130554 |
2? |
51.3-51.9 |
54.8-55.4 |
110 |
20 |
|
S06290672 |
SS06290672 |
2-1/2? |
62.9-63.6 |
66.5-67.2 |
130 |
10 |
|
S07790824 |
SS07790824 |
3? |
77.9-78.7 |
81.6-82.4 |
155 |
10 |
|
S10161026 |
SS10161026 |
4? |
101.6-102.6 |
105.5-106.5 |
200 |
5 |
S conduit is used where high mechanical strength
or high flexibility are required or where high temperatures are
experienced. In addition, being inherently a low fire hazard
product. It is suitable for under-floor wiring applications.
? IP RATING: IP 40
? WORKING TEMPERATURES:
0C-300C
? COLOUR: Gray zinc self
color
? COMPRESSION
STRENGTH(20mm): 2400N at 10% permanent deformation over 50mm
length
? PULL OFF STRENTH OF
CONDUIT(20mm): 1500N
SS Conduit, a product for use where corrosion
resistance is required due to damp or ourtdoor applications or where
low and high temperatures may be encountered. It is constructed from
stainless steel (grade 316) strip which is profiled and helically
wound into a flexible conduit.
IP RATING: IP40
? WORKING TEMPERATURES:
-50C-300C
? COLOUR: Grey zinc self
color
? COMPRESSION
STRENGTH(20mm): 2400N at 10% permanent deformation over 50mm
length
? PULL OFF STRENGTH OF
CONDUIT (20mm): 1500N
TYPE SP & TYPE LFH-SP
|
Type SP
Part No. |
Type LFH-SP
Part No. |
Nominal Size
(inch) |
I.D
(mm) |
O.D
(mm) |
Bend Radius
(mm) |
Reeled Lengths
(m) |
|
SP00970145 |
LFH-SP00971045 |
1/4? |
9.7-10.2 |
14.0-14.5 |
55 |
50 |
|
SP01230167 |
LFH-SP01230172 |
3/8? |
12.3-12.8 |
16.7-17.2 |
60 |
50 |
|
SP01580202 |
LFH-SP01580207 |
1/2? |
15.8-16.3 |
20.2-20.7 |
85 |
50 |
|
SP02080251 |
LFH-SP02080261 |
3/4? |
20.8-21.3 |
25.5-26.1 |
100 |
50 |
|
SP02640307 |
LFH-SP02640322 |
1? |
26.4-27.1 |
31.6-32.2 |
120 |
50 |
|
SP03500392 |
LFH-SP03500415 |
1-1/4? |
35.0-35.8 |
40.8-41.5 |
150 |
25 |
|
SP04010449 |
LFH-SP04010472 |
1-1/2? |
40.1-40.6 |
46.6-47.2 |
180 |
25 |
|
SP05130564 |
LFH-SP05130587 |
2? |
51.3-51.9 |
58.1-58.7 |
220 |
20 |
|
SP06290681 |
LFH-SP06290724 |
2-1/2? |
62.9-63.6 |
71.8-72.4 |
310 |
10 |
|
SP 07790834 |
LFH-SP07790879 |
3? |
77.9-78.7 |
87.2-87.9 |
350 |
10 |
|
SP 10161074 |
LFH-SP10161123 |
4? |
101.6-102.6 |
111.2-112.3 |
410 |
5 |
SP conduit is extremely versatile and can be used
in most industrial and commercial environments. It can be used in
limited dynamic and in static applications e.g. to facilitate the
installation of rigid conduit or trunking. The PVC coating affords a
degree of weather proofing and protection.
? CONSTRUCTIN: Galvanized
steel core, PVC jacketed.
? IP RATING: IP54.
? WORKING TEMPERATURES:
-20C-90C
? COLOR: Standard black,
grey.
? COMPRESSION STRENGTH
(20mm): 2400N at 10% permanent deformation over 50mm length.
? PULL OFF STRENGTH OF
CONDUIT (20mm): 1500N.
LFH-SP CONDUIT. The highly flame retardant, low
toxicity, low smoke density and Halogen free properties of the outer
sheath of this product make it ideal for use in those areas where
fire is of particular concern, e.g. underground, tunnels, hospitals,
high rise office blocks and public buildings. Electrical engineers
can now specify a flexible conduit which is compatible with Low
Smoke cable.
? IP RATING: IP54.
? WORKING TEMPERATURES:
-10C-90C
? COLOR: Standard black,
grey.
? COMPRESSION STRENGTH
(20mm): 2400N at 10% permanent deformation over 50mm length.
? PULL OFF STRENGTH OF
CONDUIT (20mm): 1500N.
TYPE SPL
|
TYPE SPL
Part No. |
Nominal Size
(inch) |
I.D
(mm) |
O.D
(mm) |
Bend Radius
(mm) |
Reeled Lengths
(m) |
|
SPL01230180 |
3/8? |
12.3-12.8 |
17.5-18.0 |
60 |
50 |
|
SPL01580213 |
1/2? |
15.8-16.3 |
20.8-21.3 |
80 |
50 |
|
SPL02080267 |
3/4? |
20.8-21.3 |
26.3-26.7 |
100 |
30 |
|
SPL02640334 |
1? |
26.4-27.1 |
32.7-33.4 |
150 |
30 |
|
SPL03500422 |
1-1/4? |
35.0-35.8 |
41.4-42.2 |
180 |
20 |
|
SPL04010483 |
1-1/2? |
40.1-40.6 |
47.4-48.3 |
220 |
20 |
|
SPL05130519 |
2? |
51.3-51.9 |
59.4-60.3 |
250 |
15 |
|
SPL06290730 |
2-1/2? |
62.9-63.6 |
72.1-73.0 |
300 |
10 |
|
SPL07790889 |
3? |
77.9-78.7 |
87.9-88.9 |
450 |
10 |
|
SPL10161143 |
4? |
101.6-102.6 |
113.2-114.3 |
600 |
5 |
A liquid tight system developed for higher
temperature applications such as machine tools and/or where the
conduit will be required to operate in environments where oils and
greases are predominant.
? CONSTRUCTION:
Electro-galvanized steel strip which is then profiled and
helically wound into a flexible conduit. It is then coated with
heavy duty PVC, with a smooth surface enabling the fitting to seal
completely when assembled. The grade of PVC selected allows
greater resistance to wide range of oils and greases.
? IP RATING: IP67.
? WORKING TEMPERATURES:
-20C-120C
? COLOR: Standard black
(UV resistance), grey.
? COMPRESSION STRENGTH
(20mm): 3000N at 10% permanent deformation over 50mm length.
? PULL OFF STRENGTH OF
CONDUIT (20mm): 1700N.
TYPE PA
|
TYPE PA
Nominal Size |
I.D
(mm) |
O.D
(mm) |
Bend Radius
(mm) |
Reeled Lengths
(m) |
|
PA10.0 |
6.5 |
10.0 |
16 |
50 |
|
PA13.0 |
10.0 |
13.0 |
20 |
50 |
|
PA15.8 |
12.0 |
15.8 |
30 |
50 |
|
PA18.5 |
14.3 |
18.5 |
40 |
50 |
|
PA21.2 |
17.0 |
21.2 |
45 |
50 |
|
PA28.5 |
23.0 |
28.5 |
50 |
30 |
|
PA42.5 |
36.0 |
42.5 |
70 |
30 |
|
PA54.5 |
48.0 |
54.5 |
90 |
30 |
? Material: Nylon 66.
? Characteristics with
high flexibility and good bending.
? IP rating: IP66.
? Working Temperature:
-50-115C
? Color: Black (UV
resistant) and grey (RAL7031).
? Anti-oil, anti-acid
and anti-corrosion.
? Fire resistant
TYPE SB
|
Nominal Size |
I.D |
Part No. |
O.D |
Bend Radius |
ReeledLengths |
|
3/8? |
12.3-12.8 |
SB01230168 |
16.3-16.8 |
70 |
50 |
|
1/2? |
15.8-16.3 |
SB01580203 |
19.7-20.3 |
90 |
50 |
|
3/4? |
20.8-21.3 |
SB02080252 |
24.7-25.2 |
110 |
50 |
|
1? |
26.4-27.1 |
SB02640308 |
30.2-30.8 |
150 |
50 |
|
1-1/4? |
35.0-35.8 |
SB03500393 |
38.7-39.3 |
175 |
25 |
|
1-1/2? |
40.1-40.6 |
SB04010450 |
44.4-45.0 |
200 |
25 |
|
2? |
51.3-51.9 |
SB05130564 |
55.8-56.4 |
230 |
20 |
|
2-1/2? |
62.9-63.6 |
SB06290682 |
67.5-68.2 |
250 |
10 |
|
3? |
77.9-78.7 |
SB07790824 |
81.6-82.4 |
300 |
10 |
|
4? |
101.6-102.6 |
SB10161065 |
105.5-106.5 |
500 |
5 |
SB conduit is used in applications where high
temperatures are experienced. In addition to being a Low Fire Hazard
product, the electro-galvanized steel wire over-braid increases the
resistance to abrasion and mechanical damage.
? CONSTRUCTION:
Electro-galvanized steel strip which is then profiled and
helically wound into a flexible conduit. This is then over-braided
with electro-galvanized steel wire.
? IP RATING: IP40.
? WORKING TEMPERATURES:
0C-300C
? COLOR: Grey zinc self
color.
? COMPRESSION STRENGTH
(20mm): 2400N at 10% permanent deformation over 50mm length.
? PULL OFF STRENGTH OF
CONDUIT (20mm): 1650N.
EXPLOSION-PROOF METAL HOSE (SUPER SOFT TYPE)
TYPE SPB
|
Nominal Size |
I.D |
Part No. |
O.D |
Bend Radius |
Reeled Lengths |
|
3/8? |
12.3-12.8 |
SPB01230190 |
18.5-19.0 |
70 |
50 |
|
1/2? |
15.8-16.3 |
SPB01580223 |
21.8-22.3 |
90 |
50 |
|
3/4? |
20.8-21.3 |
SPB02080277 |
27.2-27.7 |
110 |
50 |
|
1? |
26.4-27.1 |
SPB02640344 |
33.7-34.4 |
150 |
50 |
|
1-1/4? |
35.0-35.8 |
SPB03500432 |
42.5-43.2 |
175 |
25 |
|
1-1/2? |
40.1-40.6 |
SPB04010493 |
48.4-49.3 |
200 |
25 |
|
2? |
51.3-51.9 |
SPB05130613 |
60.4-61.3 |
230 |
20 |
|
2-1/2? |
62.9-63.6 |
SPB06290740 |
73.1-74.0 |
250 |
10 |
|
3? |
77.9-78.7 |
SPB07790899 |
88.8-89.9 |
300 |
10 |
|
4? |
101.6-102.6 |
SPB10161153 |
114.2-115.3 |
500 |
5 |
SPB conduit is used in applications where a
degree of weather-proofing and water resistance is required and
there is a need to protect the PVC sheathing from mechanical damage
such as abrasion and hot swarf.
? CONSTRUCTION:
Electro-galvanized steel strip which is then profiled and
helically wound into a flexible conduit. It is then coated with a
uniform thickness of plastic PVC. This is then over-braided with
electro-galvanized steel wire.
? IP RATING: IP54.
? WORKING TEMPERATURES:
0C-90C
? COLOR: Grey zinc self
color.
? COMPRESSION STRENGTH
(20mm): 2400N at 10% permanent deformation over 50mm length.
? PULL OFF STRENGTH OF
CONDUIT (20mm): 1750N.
TYPE-M180 & M090 & M045
|
TYPE M180
Part No. |
TYPE M090
Part No. |
TYPE M045
Part No. |
Nominal size
(inch) |
Size (mm) |
Reeled Lengths
(m) |
|
I.D |
A |
B |
C |
|
M180014011 |
M090014011 |
M045014011 |
1/4? |
11.00 |
12.70 |
15.70 |
25.40 |
5 0 |
|
M180038014 |
M090038014 |
M045038014 |
3/8? |
14.00 |
12.70 |
19.70 |
25.40 |
5 0 |
|
M180012014 |
M090012014 |
M045012014 |
1/2? |
14.00 |
12.70 |
19.70 |
28.50 |
5 0 |
|
M180034018 |
M090034018 |
M045034018 |
3/4? |
18.80 |
14.25 |
24.70 |
35.00 |
5 0 |
|
M180100024 |
M090100024 |
M045100024 |
1? |
24.70 |
16.20 |
31.70 |
41.30 |
2 5 |
|
M180114032 |
M090114032 |
M045004032 |
1-1/4? |
32.80 |
18.20 |
39.70 |
57.00 |
2 0 |
|
M180112038 |
M090112038 |
M045112038 |
1-1/2? |
38.50 |
18.20 |
49.70 |
63.00 |
1 0 |
|
M180200049 |
M090200049 |
M045200049 |
2? |
49.80 |
20.00 |
62.70 |
76.00 |
1 0 |
|
| | |