Products

News

中文   
 

         Contact:

          
       Tel: +86-10-87709858          
       Fax: +86-10-87709228         
       E-mail: info@farAsia.com.cn
 
         Add:
         1401, No. 12 Bldg,
         Panjiayuan Nanli,
         Chaoyang, Beijing, 100021, China

 

 

 

 

 

 

Apogee 800 ultrasound system

The Apogee 800Plus ultrasound system offers a new level of high quality in image. With broad clinical application, the systemdelivers ease of use for cardiac and vascular exams.

Due to the exceptional image quality, the sensitivity of color Doppler and many other advanced features, the Apogee 800Plus offers complete diagnosis capability for your entire patient population, including abdominal, obstetrics, gynecology, adult cardiology, pediatric cardiology, peripheral vascular, small parts, breast, prostate, transcranial, etc.

The Apogee 800Plus system can meet nearly all scanning requirements. The multi-frequency sound velocity forming capability provides a broad frequency range from 2-12 MHz, which allows the clinical doctors to select the best frequency for specific exams and patients. The multi-frequency feature enhances the image definition as well as penetration. Therefore, there is no need to purchase so many probes for different uses.
 
 

 

   

System Specifications

Physical Dimensions:

  • Width:68.58 cm (27 in)
  • Height:145.11 cm (57.13 in),111.40 cm (43.86 in) when monitor is removed for transport             
  • Depth:86.36 cm (34 in)
  • Weight: 140Kg  (310 lbs) (without peripherals)

System Architecture:

  • Broadband beamformer
  • Modular microcomputer structure
  • System software upgradable through floppy disk

Applications:

  • Abdominal
  • Cardiac
  • Fetal Echocardiography
  • Gynecological
  • Neonate
  • Obstetrics
  • Small Parts
  • Transrectal
  • Vascular

Time Gain Compensation:

  • Slidepot controls
  • 2D gain rotary control
  • Color flow gain rotary control

Update Methods:

  • Update or Duplex
  • Simultanecous

Gray Shades/Color Shades:

  • 256 in 2D
  • 128 in M-mode
  • 128 in Doppler
  • 128 in Color

Operator Control System:

  • Monitor brighmess and contrast controls
  • Rotary controls
  • Slidepot controls
  • Keyboard
  • Volume control
  • Dedicated primary imaging controls
  • Menus and special function keys for secondary imaging controls

Progammability:

  • Application and scanhead optimization
  • Customer settings saved by application and scanhead
  • On-screen progamming for internal and external hardcopy devices

Imaging Modes:

  • 2D
  • M-mode
  • Pulsed wave Doppler
  • Continuous wave Doppler
  • Color Power Angio Imaging
  • Color 2D
  • Color M-mode
  • High PRF Doppler

Image Processing:

  • 2D Graymaps
  • Dynamic contrast enhancement
  • 2D and color persistence
  • Variable line density up to 256 lines
  • 2-24 cm depth settings
  • 20?150?sector angles in 5?increments
  • 1,2, or 4 second sweep speeds
  • Chroma color tissue mapping of 2D, M-mode, and spectral displays
  • Doppler Graymaps
  • Color maps
  • Triple mode simultaneous

Image and Data Memory:

  • Full resolution freeze frame
  • 6-281 saved 2D images
  • 3-166 saved M-mode screens
  • 19-128 Cineloop frames
  • 11-75 M-mode review screens

Scan Conversion:

  • Sector for symmetric phased array and curved array scanheads
  • Rectangular for linear array scanheads
  • Up to 512 scan lines (scanhead dependent)

Image Modification:

  • Zoom and pan of real-time or frozen 2D image
  • Color persistence
  • 2D persistence
  • Apex invert
  • Left/right reverse
  • Video invert for M-mode

Display Annotation:

  • Patient name and identification
  • Scanhead type, frequency, and broadband range
  • Image depth
  • Exam type
  • Time and date
  • Contorl window settings
  • Biopsy guide lines
  • Application-specific anatomic annotation
  • Encrypted (abbreviated) information feature
  • Output power in ISPTA and % or db

Scanhead

Scanheads:

  • Linear Array, 7-4 40mm
  • Linear Array, 11-5 40 mm
  • Curved Array, 5-2 40mm
  • Curved Array, 5-2 76mm
  • Curved Array, 7-3 40mm
  • Curved Array, 4-2 15mm
  • Curved Array, 6-3 13mm
  • Curved Array, 8-5 11mm
  • Curved Array, 9-5 8mm Endo
  • Symmetric Phased Array, 2.75 19mm
  • Symmetric Phased Array, 3.5 19mm
  • Symmetric Phased Array, 3.5 25mm
  • Symmetric Phased Array, 5.0 19mm
  • Symmetric Phased Array, 5.0 25mm
  • Phased Array, 7-5 11.5mm Multiplane TEE
  • Symmetric Phased Array, 7-5 15mm

Biopay Guide Availability:

  • Linear Array, 7-4 40mm
  • Linear Array, 11-5 40 mm
  • Curved Array, 5-2 40mm
  • Curved Array, 7-3 40mm
  • Curved Array, 4-2 15mm
  • Curved Array, 9-5 8mm Endo

Static Pencil Probes:

  • Doppler, 2.0 13.8mm CW, PW
  • Doppler, 2.0 16mm Transcranial PW
  • Doppler, 5.0 10mm CW, PW
  • Doppler, 10.0 3.5mm CW, PW

Image

2D:

  • Image orientation marker
  • Selectable graymaps
  • Up to 8 transmit focal zones
  • 2D persistence
  • Dynamic range
  • 2D sector angle (or linear width) and steering

M-Mode:

  • Three sweep speeds
  • Time markers
  • M-mode review
  • M-mode zoom

Doppler:

  • Wall filters
  • Pulsed wave
  • Continuous wave
  • Adjustable sample volume (1.3-29.5mm)
  • Adjustable baseline
  • Normal or inverted display
  • Three sweep speeds
  • Doppler review
  • Doppler processing curves
  • Angle correction

Color:

  • 2D Color
  • Selectable maps
  • Color persistence

Power:

  • 2D Color Power Angio Imaging
  • Selectable maps
  • Adjustable background-on or off
  • Persistence

Analysis:

  • General imaging
  • Obstetrical
  • Cardiology
  • Vascular

Measurement Tools:

  • Distance
  • Area/perimeter
  • Ellipse
  • Volume
  • Angle
  • Slope
  • Time
  • Heart rate

Image Storage and Retrieval:

  • Cineloop Image Review
  • Doppler Review
  • M-mode Review
  • VCR Playback

Optional Hardcopy Devices:

  • Super VHS VCR
  • Multi-Imaging camera
  • Color printer
  • Black-and-white printer

External Connections

  • RGB-S (Red, Green, Blue, and Sync) video output, 50/60 Hz frame rate, non-interlaced for external video monitors: BNC connectors
  • Composite video output: BNC connectors
  • Composite video intput: BNC connectors
  • VCR-S video output: S-video connector
  • VCR-S video input: S-video connector
  • Audio output (left/right): BNC connector
  • VCR audio input (left/right): dual RCA jacks
  • ECG trigger input: BNC connector
  • ECG input: standard 6-pin ECG connector
  • ECG signal output: BNC connector
  • Microphone input: miniature (1/8") phone jack
  • Physio input: 1/4" phone jack
  • Footswitch: Sub-D 9-pin
  • Additional footswitch: miniature (1/8") phone jack
  • RS-232A serial port: Sub-D 9-pin connector

Use Environment

Electrical and Video Parameters:

  • Power:

   

- 115Vac, (V~), @ 50 to 60 Hz, 1.2kVA

   

- 230Vac, (V~), @ 50 to 60 Hz, 1.2kVA

  

- Power consumption:800 Watts

     

   ( with optional OEM'S:1200 Watts max)

  • Integral AC line conditioner

Monitor:

  • one 15-inch(38 cm), high-resolution, color monitor

Languages:

  • English
  • Chinese
  • French
  • German
  • Spanish
  • Italian

Storage:

  • Unified cable managements system
  • General purpose tray
  • General purpose drawer (optional)

Safety Requirements:

  • Classification:

 

- Class 1 with Type BF and CF applied parts

 

- Ordinary Equipment

 

- Non-AP/APG

  • Electromechanical safety standards meet:

 

- EN 60601-1, European Norm, Medical Electrical Equipment

 

- EN 60601-1-2, European Norm, Electromagnetic Compatibility

 

- CSA C22.2 No. 601.1, Canadian Standards Association, Medical Electrical Equipment

 

- UL 544, Underwriter's Laboratories, Medical and Dental Equipment

  • Agency approvals:

 

- Electrical Testing Laboratories, Inc. (ETL)

 

- French Ministry of Social Affairs (GMED)

Temperature, Pressure, and Humidity Limits:

  • Storage and Shipping

         - High:65       Low: -34 

         - All at 1060 hPa to 500 hPa (1.05 ATM to 0.5 ATM)

         - 10% to 95% relative humidity

  • Operation Environment

         - High:35 Low: 16 

         - All at 1060 hPa to 700 hPa (1.05 ATM to 0.7 ATM)

         - 30% to 75% relative humidity

 

Hit Counter     
Send mail to info@farAsia.com.cn with questions or comments.
Copyright © 2003 Far Asia Co., Ltd (China) 
Last modifie
d: 03/01/08