Vibration Transducer Calibrator Model
VM-3B

Brief Description The model
VM-3B, Vibration Transducer Calibrator, is a useful with capability
of generate broad-band signal for system frequency response test.
All accessories of Shaker can be mounted inside the portable housing
of VM-3B that leaves no extra accessories to be carried during the
field operation. VM-3B utilizes advanced digital technology. The
waveform was generated via a digital signal source which is
precisely controlled by the internal clock of the digital circuitry.
The result is a sine-wave with high accuracy in both waveform and
frequency. VM-3b will calibrate sensors with frequency 10Hz, 20Hz,
40Hz, 80Hz, 160Hz, 320Hz, 640Hz and 1280Hz. VM-3B has all the
accessories to meet your need. The accessories include linearity
calibration kit for proximity probe transducer, dynamic calibration
kit for proximity probe transducer.
- Field calibration of vibration monitoring systems
- Field calibration of both seismic and proximity probe
sensors
- Digital accuracy in frequency, waveform and display
- Reading in acceleration, velocity and displacement until
with English/Metric, Peak/RMS
Technical specifications
|
Model |
VM-3B |
|
Frequency |
10Hz, 20Hz, 40Hz, 80Hz, 160Hz, 320Hz, 640Hz & 1280Hz. |
|
Calibration |
2g-5g at 80Hz |
|
Display |
3 digits display |
|
Unit |
Acceleration: m/s2 (g) |
|
Velocity: mm/sec (inch/sec) |
|
Displacement: um (mil) |
|
Measurement |
0-peak: acceleration |
|
RMS: Velocity |
|
Peak-peak: Displacement |
|
Amplitude Max. Range |
At 80Hz, <100g |
|
Acceleration: < 98 m/s2 (10g) pk |
|
Velocity: <125 mm/sec (5in/sec) |
|
Displacement: 750um (30mil) pk-pk |
|
Amplitude Accuracy |
Acceleration (at 30m/s2 pk, 80Hz) |
|
40Hz to 320Hz +/-0.3dB +/-1digit |
|
10Hz to 1280Hz +/-0.5dB +/-1digit |
|
Velocity: (at 25mm/sec pk, 80Hz) |
|
40Hz to 320Hz +/-0.5dB +/- 1digit |
|
Displacement (at 10um pk-pk, 80Hz) |
|
40Hz-320Hz, +/-0.5dB +/- 1digit |
|
Linearity |
+/-1% (100gm load) |
|
Proximity Probe Linearity |
Probe: 5mm & 8mm Probe |
|
Range” 0-4.0mm |
|
Working Environment |
Temperature: 0-50°C (30-125°F ) |
|
Storage: -20°C to 70°C |
|
Humidity: 90% non-condensing |
|
Size |
280*180*250mm |
|
Weight |
7kg |
Relationship of Max. Load & Max.
Frequency
|
Weight |
≤100g |
≤250g |
≤650g |
|
Frequency |
a (m/S2) |
v (mm/S) |
d (μ m) |
(m/S2) |
v (mm/S) |
d (μ m) |
a (m/S2) |
v (mm/S) |
d (μ m) |
|
10Hz |
2.5 |
28 |
1300 |
3.5 |
40 |
1800 |
4 |
45 |
2000 |
|
20Hz |
15 |
85 |
1900 |
10 |
60 |
1300 |
5 |
28 |
640 |
|
40Hz |
60 |
170 |
2000 |
35 |
100 |
1100 |
12 |
35 |
380 |
|
80Hz |
100 |
141 |
800 |
40 |
60 |
320 |
14 |
20 |
110 |
|
160Hz |
75 |
53 |
150 |
35 |
25 |
70 |
12 |
8.5 |
24 |
|
320Hz |
50 |
18 |
25 |
30 |
10 |
15 |
10 |
3.5 |
5 |
|
640Hz |
30 |
5 |
3 |
20 |
3.9 |
2 |
6 |
1 |
* |
|
1280Hz |
23 |
2 |
* |
10 |
0.9 |
* |
5 |
0.4 |
* |
Standard Delivery
- Main Unit
- Cable
- Warranty Card
- Certificate
- Instruction Manual
|
|